Subject: hwmon/ds1621: Fix swapped temperature limits The low temperature limit and the high temperature limit registers have been accidentally swapped, causing alarms to trigger when they shouldn't. Signed-off-by: Jean Delvare Cc: Aurelien Jarno --- drivers/hwmon/ds1621.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) --- linux-2.6.22-rc1.orig/drivers/hwmon/ds1621.c 2007-02-04 19:44:54.000000000 +0100 +++ linux-2.6.22-rc1/drivers/hwmon/ds1621.c 2007-05-16 17:39:56.000000000 +0200 @@ -53,8 +53,8 @@ MODULE_PARM_DESC(polarity, "Output's pol /* The DS1621 registers */ #define DS1621_REG_TEMP 0xAA /* word, RO */ -#define DS1621_REG_TEMP_MIN 0xA1 /* word, RW */ -#define DS1621_REG_TEMP_MAX 0xA2 /* word, RW */ +#define DS1621_REG_TEMP_MIN 0xA2 /* word, RW */ +#define DS1621_REG_TEMP_MAX 0xA1 /* word, RW */ #define DS1621_REG_CONF 0xAC /* byte, RW */ #define DS1621_COM_START 0xEE /* no data */ #define DS1621_COM_STOP 0x22 /* no data */ @@ -328,9 +328,9 @@ static struct ds1621_data *ds1621_update /* reset alarms if necessary */ new_conf = data->conf; - if (data->temp < data->temp_min) + if (data->temp > data->temp_min) new_conf &= ~DS1621_ALARM_TEMP_LOW; - if (data->temp > data->temp_max) + if (data->temp < data->temp_max) new_conf &= ~DS1621_ALARM_TEMP_HIGH; if (data->conf != new_conf) ds1621_write_value(client, DS1621_REG_CONF,