GIT 75d8807962fc7529b4946e9ec92cae197be5a967 git://git.infradead.org/battery-2.6.git commit 75d8807962fc7529b4946e9ec92cae197be5a967 Author: Andres Salomon Date: Wed May 14 16:20:38 2008 -0700 power_supply: fix up CHARGE_COUNTER output to be more precise As Richard Smith pointed out, ACR * 6250 / 15 provides for less precision loss than ACR * 4167 / 10, _and_ it doesn't overflow. Switch to using that equation for CHARGE_COUNTER. Signed-off-by: Andres Salomon Cc: "Richard A. Smith" Signed-off-by: Andrew Morton Signed-off-by: Anton Vorontsov commit 8e552c36d90c03d2cabf5373788998966751b609 Author: Andres Salomon Date: Mon May 12 21:46:29 2008 -0400 power_supply: add CHARGE_COUNTER property and olpc_battery support for it This adds PROP_CHARGE_COUNTER to the power supply class (documenting it as well). The OLPC battery driver uses this for spitting out its ACR values (in uAh). We have some rounding errors (the data sheet claims 416.7, the math actually works out to 416.666667, so we're forced to choose between overflows or precision loss. I chose precision loss, and stuck w/ data sheet values), but I don't think anyone will care that much. Signed-off-by: Andres Salomon Signed-off-by: Anton Vorontsov commit 484d6d50cca3941db6e063113d124333aed0abc0 Author: Andres Salomon Date: Fri May 2 13:41:59 2008 -0700 power_supply: bump EC version check that we refuse to run with in olpc_battery Refuse to run with an EC < 0x44. We're playing it safe, and this is a pretty old EC version. Also, add a comment about why we're checking the EC version. Signed-off-by: Andres Salomon Cc: David Woodhouse Signed-off-by: Andrew Morton Signed-off-by: Anton Vorontsov commit b2bd8a3bcdd18101eb5d85c267c1a1fb8ce9acc7 Author: Andres Salomon Date: Fri May 2 13:41:59 2008 -0700 power_supply: cleanup of the OLPC battery driver Move portions of the massive switch statement into functions. The layout of this thing has already caused one bug (a break in the wrong place), it needed to shrink. Signed-off-by: Andres Salomon Cc: David Woodhouse Signed-off-by: Andrew Morton Signed-off-by: Anton Vorontsov commit d7eb9e36c42504e87c7d92dd5c05cb6f2cf74d28 Author: Andres Salomon Date: Fri May 2 13:41:58 2008 -0700 power_supply: add eeprom dump file to olpc_battery's sysfs This allows you to dump 0x60 bytes from the battery's EEPROM (starting at address 0x20). Note that it does an EC command for each byte, so it's pretty slow. OTOH, if you want to grab just a single byte from somewhere in the EEPROM, you can do something like: dd bs=1 count=1 skip=16 if=/sys/class/power_supply/olpc-battery/eeprom | od -x Userspace battery collection/logging information needs this. Signed-off-by: Andres Salomon Cc: David Woodhouse Signed-off-by: Andrew Morton Signed-off-by: Anton Vorontsov commit 1ca5b9d2183f11bb8b69e04b19a7faf7f600a840 Author: David Woodhouse Date: Sun May 4 01:31:42 2008 -0400 power_supply: Support serial number in olpc_battery This adds serial number support to the OLPC battery driver. Signed-off-by: David Woodhouse Signed-off-by: Andres Salomon Signed-off-by: Anton Vorontsov Documentation/power/power_supply_class.txt | 4 + drivers/power/olpc_battery.c | 273 ++++++++++++++++++++-------- drivers/power/power_supply_sysfs.c | 1 + include/linux/power_supply.h | 1 + 4 files changed, 203 insertions(+), 76 deletions(-) diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index a8686e5..c6cd495 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -101,6 +101,10 @@ of charge when battery became full/empty". It also could mean "value of charge when battery considered full/empty at given conditions (temperature, age)". I.e. these attributes represents real thresholds, not design values. +CHARGE_COUNTER - the current charge counter (in µAh). This could easily +be negative; there is no empty or full value. It is only useful for +relative, time-based measurements. + ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. CAPACITY - capacity in percents. diff --git a/drivers/power/olpc_battery.c b/drivers/power/olpc_battery.c index ab1e828..32570af 100644 --- a/drivers/power/olpc_battery.c +++ b/drivers/power/olpc_battery.c @@ -19,7 +19,7 @@ #define EC_BAT_VOLTAGE 0x10 /* uint16_t, *9.76/32, mV */ #define EC_BAT_CURRENT 0x11 /* int16_t, *15.625/120, mA */ -#define EC_BAT_ACR 0x12 +#define EC_BAT_ACR 0x12 /* int16_t, *6250/15, µAh */ #define EC_BAT_TEMP 0x13 /* uint16_t, *100/256, °C */ #define EC_AMB_TEMP 0x14 /* uint16_t, *100/256, °C */ #define EC_BAT_STATUS 0x15 /* uint8_t, bitmask */ @@ -84,6 +84,119 @@ static struct power_supply olpc_ac = { .get_property = olpc_ac_get_prop, }; +static char bat_serial[17]; /* Ick */ + +static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte) +{ + if (olpc_platform_info.ecver > 0x44) { + if (ec_byte & BAT_STAT_CHARGING) + val->intval = POWER_SUPPLY_STATUS_CHARGING; + else if (ec_byte & BAT_STAT_DISCHARGING) + val->intval = POWER_SUPPLY_STATUS_DISCHARGING; + else if (ec_byte & BAT_STAT_FULL) + val->intval = POWER_SUPPLY_STATUS_FULL; + else /* er,... */ + val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; + } else { + /* Older EC didn't report charge/discharge bits */ + if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */ + val->intval = POWER_SUPPLY_STATUS_DISCHARGING; + else if (ec_byte & BAT_STAT_FULL) + val->intval = POWER_SUPPLY_STATUS_FULL; + else /* Not _necessarily_ true but EC doesn't tell all yet */ + val->intval = POWER_SUPPLY_STATUS_CHARGING; + } + + return 0; +} + +static int olpc_bat_get_health(union power_supply_propval *val) +{ + uint8_t ec_byte; + int ret; + + ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1); + if (ret) + return ret; + + switch (ec_byte) { + case 0: + val->intval = POWER_SUPPLY_HEALTH_GOOD; + break; + + case BAT_ERR_OVERTEMP: + val->intval = POWER_SUPPLY_HEALTH_OVERHEAT; + break; + + case BAT_ERR_OVERVOLTAGE: + val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE; + break; + + case BAT_ERR_INFOFAIL: + case BAT_ERR_OUT_OF_CONTROL: + case BAT_ERR_ID_FAIL: + case BAT_ERR_ACR_FAIL: + val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE; + break; + + default: + /* Eep. We don't know this failure code */ + ret = -EIO; + } + + return ret; +} + +static int olpc_bat_get_mfr(union power_supply_propval *val) +{ + uint8_t ec_byte; + int ret; + + ec_byte = BAT_ADDR_MFR_TYPE; + ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + if (ret) + return ret; + + switch (ec_byte >> 4) { + case 1: + val->strval = "Gold Peak"; + break; + case 2: + val->strval = "BYD"; + break; + default: + val->strval = "Unknown"; + break; + } + + return ret; +} + +static int olpc_bat_get_tech(union power_supply_propval *val) +{ + uint8_t ec_byte; + int ret; + + ec_byte = BAT_ADDR_MFR_TYPE; + ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + if (ret) + return ret; + + switch (ec_byte & 0xf) { + case 1: + val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH; + break; + case 2: + val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe; + break; + default: + val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; + break; + } + + return ret; +} + /********************************************************************* * Battery properties *********************************************************************/ @@ -94,6 +207,7 @@ static int olpc_bat_get_property(struct power_supply *psy, int ret = 0; int16_t ec_word; uint8_t ec_byte; + uint64_t ser_buf; ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &ec_byte, 1); if (ret) @@ -110,25 +224,10 @@ static int olpc_bat_get_property(struct power_supply *psy, switch (psp) { case POWER_SUPPLY_PROP_STATUS: - if (olpc_platform_info.ecver > 0x44) { - if (ec_byte & BAT_STAT_CHARGING) - val->intval = POWER_SUPPLY_STATUS_CHARGING; - else if (ec_byte & BAT_STAT_DISCHARGING) - val->intval = POWER_SUPPLY_STATUS_DISCHARGING; - else if (ec_byte & BAT_STAT_FULL) - val->intval = POWER_SUPPLY_STATUS_FULL; - else /* er,... */ - val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; - } else { - /* Older EC didn't report charge/discharge bits */ - if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */ - val->intval = POWER_SUPPLY_STATUS_DISCHARGING; - else if (ec_byte & BAT_STAT_FULL) - val->intval = POWER_SUPPLY_STATUS_FULL; - else /* Not _necessarily_ true but EC doesn't tell all yet */ - val->intval = POWER_SUPPLY_STATUS_CHARGING; - break; - } + ret = olpc_bat_get_status(val, ec_byte); + if (ret) + return ret; + break; case POWER_SUPPLY_PROP_PRESENT: val->intval = !!(ec_byte & BAT_STAT_PRESENT); break; @@ -137,72 +236,21 @@ static int olpc_bat_get_property(struct power_supply *psy, if (ec_byte & BAT_STAT_DESTROY) val->intval = POWER_SUPPLY_HEALTH_DEAD; else { - ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1); + ret = olpc_bat_get_health(val); if (ret) return ret; - - switch (ec_byte) { - case 0: - val->intval = POWER_SUPPLY_HEALTH_GOOD; - break; - - case BAT_ERR_OVERTEMP: - val->intval = POWER_SUPPLY_HEALTH_OVERHEAT; - break; - - case BAT_ERR_OVERVOLTAGE: - val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE; - break; - - case BAT_ERR_INFOFAIL: - case BAT_ERR_OUT_OF_CONTROL: - case BAT_ERR_ID_FAIL: - case BAT_ERR_ACR_FAIL: - val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE; - break; - - default: - /* Eep. We don't know this failure code */ - return -EIO; - } } break; case POWER_SUPPLY_PROP_MANUFACTURER: - ec_byte = BAT_ADDR_MFR_TYPE; - ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + ret = olpc_bat_get_mfr(val); if (ret) return ret; - - switch (ec_byte >> 4) { - case 1: - val->strval = "Gold Peak"; - break; - case 2: - val->strval = "BYD"; - break; - default: - val->strval = "Unknown"; - break; - } break; case POWER_SUPPLY_PROP_TECHNOLOGY: - ec_byte = BAT_ADDR_MFR_TYPE; - ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + ret = olpc_bat_get_tech(val); if (ret) return ret; - - switch (ec_byte & 0xf) { - case 1: - val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH; - break; - case 2: - val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe; - break; - default: - val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; - break; - } break; case POWER_SUPPLY_PROP_VOLTAGE_AVG: ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2); @@ -241,6 +289,22 @@ static int olpc_bat_get_property(struct power_supply *psy, ec_word = be16_to_cpu(ec_word); val->intval = ec_word * 100 / 256; break; + case POWER_SUPPLY_PROP_CHARGE_COUNTER: + ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void *)&ec_word, 2); + if (ret) + return ret; + + ec_word = be16_to_cpu(ec_word); + val->intval = ec_word * 6250 / 15; + break; + case POWER_SUPPLY_PROP_SERIAL_NUMBER: + ret = olpc_ec_cmd(EC_BAT_SERIAL, NULL, 0, (void *)&ser_buf, 8); + if (ret) + return ret; + + sprintf(bat_serial, "%016llx", (long long)be64_to_cpu(ser_buf)); + val->strval = bat_serial; + break; default: ret = -EINVAL; break; @@ -260,6 +324,50 @@ static enum power_supply_property olpc_bat_props[] = { POWER_SUPPLY_PROP_TEMP, POWER_SUPPLY_PROP_TEMP_AMBIENT, POWER_SUPPLY_PROP_MANUFACTURER, + POWER_SUPPLY_PROP_SERIAL_NUMBER, + POWER_SUPPLY_PROP_CHARGE_COUNTER, +}; + +/* EEPROM reading goes completely around the power_supply API, sadly */ + +#define EEPROM_START 0x20 +#define EEPROM_END 0x80 +#define EEPROM_SIZE (EEPROM_END - EEPROM_START) + +static ssize_t olpc_bat_eeprom_read(struct kobject *kobj, + struct bin_attribute *attr, char *buf, loff_t off, size_t count) +{ + uint8_t ec_byte; + int ret, end; + + if (off >= EEPROM_SIZE) + return 0; + if (off + count > EEPROM_SIZE) + count = EEPROM_SIZE - off; + + end = EEPROM_START + off + count; + for (ec_byte = EEPROM_START + off; ec_byte < end; ec_byte++) { + ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, + &buf[ec_byte - EEPROM_START], 1); + if (ret) { + printk(KERN_ERR "olpc-battery: EC command " + "EC_BAT_EEPROM @ 0x%x failed -" + " %d!\n", ec_byte, ret); + return -EIO; + } + } + + return count; +} + +static struct bin_attribute olpc_bat_eeprom = { + .attr = { + .name = "eeprom", + .mode = S_IRUGO, + .owner = THIS_MODULE, + }, + .size = 0, + .read = olpc_bat_eeprom_read, }; /********************************************************************* @@ -290,8 +398,14 @@ static int __init olpc_bat_init(void) if (!olpc_platform_info.ecver) return -ENXIO; - if (olpc_platform_info.ecver < 0x43) { - printk(KERN_NOTICE "OLPC EC version 0x%02x too old for battery driver.\n", olpc_platform_info.ecver); + + /* + * We've seen a number of EC protocol changes; this driver requires + * the latest EC protocol, supported by 0x44 and above. + */ + if (olpc_platform_info.ecver < 0x44) { + printk(KERN_NOTICE "OLPC EC version 0x%02x too old for " + "battery driver.\n", olpc_platform_info.ecver); return -ENXIO; } @@ -315,8 +429,14 @@ static int __init olpc_bat_init(void) if (ret) goto battery_failed; + ret = device_create_bin_file(olpc_bat.dev, &olpc_bat_eeprom); + if (ret) + goto eeprom_failed; + goto success; +eeprom_failed: + power_supply_unregister(&olpc_bat); battery_failed: power_supply_unregister(&olpc_ac); ac_failed: @@ -327,6 +447,7 @@ success: static void __exit olpc_bat_exit(void) { + device_remove_bin_file(olpc_bat.dev, &olpc_bat_eeprom); power_supply_unregister(&olpc_bat); power_supply_unregister(&olpc_ac); platform_device_unregister(bat_pdev); diff --git a/drivers/power/power_supply_sysfs.c b/drivers/power/power_supply_sysfs.c index c444d6b..82e1246 100644 --- a/drivers/power/power_supply_sysfs.c +++ b/drivers/power/power_supply_sysfs.c @@ -99,6 +99,7 @@ static struct device_attribute power_supply_attrs[] = { POWER_SUPPLY_ATTR(charge_empty), POWER_SUPPLY_ATTR(charge_now), POWER_SUPPLY_ATTR(charge_avg), + POWER_SUPPLY_ATTR(charge_counter), POWER_SUPPLY_ATTR(energy_full_design), POWER_SUPPLY_ATTR(energy_empty_design), POWER_SUPPLY_ATTR(energy_full), diff --git a/include/linux/power_supply.h b/include/linux/power_supply.h index 68ed19c..ea96ead 100644 --- a/include/linux/power_supply.h +++ b/include/linux/power_supply.h @@ -78,6 +78,7 @@ enum power_supply_property { POWER_SUPPLY_PROP_CHARGE_EMPTY, POWER_SUPPLY_PROP_CHARGE_NOW, POWER_SUPPLY_PROP_CHARGE_AVG, + POWER_SUPPLY_PROP_CHARGE_COUNTER, POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN, POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN, POWER_SUPPLY_PROP_ENERGY_FULL,